nfpa fireplace mantel clearance

  • Uncategorized

Many codes also do require fire bricks. So a mantel 6 inches deep, would be attached 18 inches above the firebox opening. Minimum clearances from the fireplace to combustible materials: From face top: 10 " From left . current CSA C22.1 Canadian Electrical Code or with the National Electrical Code; ANSI/NFPA 70 when installed in the United States. The throat shall not be less than 8 inches (203 mm) above the fireplace opening. R1001.11 Fireplace clearance. For factory built fireplaces, you always refer to the listed instructions for mantel clearances. Dboon, thanks. I have a 1960s home with a floor-to-ceiling brick fireplace. for pricing and availability. Watch out: When it comes to standards for fireplace safety codes, The National Fire Protection Association (NFPA), "is a global self-funded nonprofit organization, established in 1896, devoted to eliminating death, injury, property and economic loss due to fire, electrical and related hazards." This "EPA Sticker" is not a stick-on label despite the use of that term by some agencies. I guess you never have to get it inspected? Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances, National Fire Protection Association (NFPA) 2022, National Fire Codes Subscription Service, The value of Standards Development Organizations, Alternative Fuel Vehicles Safety Training, Reducing Wildfire Risk to People and Property, State-approved NEC and NFPA 70E electrical online training, Certification for Electrical Safety in the Workplace, Safety in living and entertainment spaces. The cross-sectional area of the passageway above the firebox, including the throat, damper and smoke chamber, shall not be less than the cross-sectional area of the flue. Clearance is measured from the surface of the nearest combustible structure, e.g., the wooden studs in the walls or baseboards or window casings or doors (swung in any position), not from the "limited combustible" wallboard or other "protection". I found the below attached NFPA 211 clearances on a stove mfg site. In the US, The National Fireplace Protection Agency (NFPA) governs clearance distances to fireplace mantels within Code 211 Standard for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances. Cloudflare is currently unable to resolve your requested domain. Width Requirements The second thing you'll need to do is measure the width and length of your fireplace on all sides. 4. This is a common question and many thanks to all the previous threads (. Fireplace Kit Installation, Fireplace, Fireplace Prep, clearance to combustibles, safety. National Fire Protection Association (NFPA) 2022. 24 ga is fine. Question about WETT clearance - top facing, mantel or trim. 2023 Design The Space | Sitemap Most of the double wall stove pipe allows for 6" clearance from wall combustibles and 8" from ceiling combustibles. This is my choice and my husband votes for the prior. So some company will sell you a product that cuts the clearance in half (just like 211). This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register. Fire safety clearance distances are measured from the closest point of the outer surface of the heating appliance to the closest point of nearby wall, floor or ceiling or to other combustible materials that might be nearby. Get an overview of the process of creating a traditional-style fireplace that burns well and meets current building codes from experienced mason Mike Mehaffey. Also for: Minnetonka 55345-rf. Why does my fireplace smoke in the house. You do not have access to www.jlconline.com. Rigid vs Flexible Chimney Liner: Which Is The Best? Privacy Policy (mod) said: PG can take a bit of criticism. Inches. Depth: A typical mantel depth is 6 to 7 inches. You must log in or register to reply here. NFPA #211-3.1 1988 - Powered by BigCommerce, 2" and 4" Beadboard | 4x8 Plywood Paneling, Classic Random Planked Collection | 4x8 Paneling, Wainscot Paneling Collection - 48Wx32H Plywood, New England Classic Wood Panel & Wainscot, Classic Traditional Raised Panel Wainscot, Design The Space Architectural Products Sales and Promotions, Wood, Stone & Marble Fireplace Mantels & Mantel Shelf FAQ's, Terms and Conditions | Delivery Information, Building Code & Clearance Information - Fireplaces Designed to Burn Wood. | Check level of fireplace and shim with sheet metal if necessary. The. 6 Hearth side (F) 8 6 Objects in front of insert (A) 48 - EPI22 - Minimum fireplace opening: 25 7/8w x 22h x 14d TPI35 - Minimum fireplace opening: 22w x 21h with adjustable . . . Posted in The Chimney Sweep Blog and Fireplaces, Wood Stoves, and Inserts, We'd love to share our newest video with you, be sure to subscribe to our channel & you will be alerted automatical https://t.co/ADYMoI20j8. from the fireplace opening if projecting more than 1-1/2 in. The site owner may have set restrictions that prevent you from accessing the site. Some zero-clearance fireplace products have labels and/or instructions listing 1/2" or more clearance to certain parts. The store will not work correctly in the case when cookies are disabled. Principles of Home Inspection: Chimneys & Wood Heating, in (Principles of Home Inspection). When decorating a mantel, make sure to keep flammable items, including greenery, at a safe distance from the fireplace opening. It is typically a non-combustible metallic label that gives the date of manufacture of the wood or pellet stove and includes this text: "U.S. Environmental Protection Agency, Certified to Comply with July, 1988 particulate emissions standards.". From contributor R: I have to agree with contributor D. Better check the local codes. Direct Vent Gas Fireplace. The floor protection for "combustible floor construction" is spelled out according to height of the legs under the stove. So if you are looking for UL listed chimney liner sold directly to homeowners, then look no further than Rockford Chimney. Contact us for more information. Pro Tip! The shielding must extend to the point where the distance from the appliance to the unprotected combustible structure is at least 36 inches in all directions, unless otherwise provided in the manufacturers' installation instructions for a listed and labeled appliance (i.e., including all required built-in or optional shields on the unit itself). 2023 The Taunton Press, Inc. All rights reserved. You will not receive a notification when a response to your question has been posted. Burn dry wood, keep your chimney clean and in the event it is a catalytic model, keep your door-gasket seal adjusted nice and tight. I did send them the question though. Pressing the Escape (ESC) button will close the modal and bring you back to where you were on the page. Apparently that is not far enough away. . It needs to extend past the stovetop. Model # 15185. Mantels above factory-built fireplaces are permitted to be closer than 12 in. Installing a fireplace mantle without adequate clearance from the fireplace opening could be a serious fire hazard and it may lead to damage and injury. Examples of unsafe wood stove installations. There is probably a way around that, but then what? 3' (91cm) above if within 10' (3m) horizontally. 2021 International Residential Code (IRC) BASIC Upgrade to Premium CHAPTER 10 CHIMNEYS AND FIREPLACES First Version: Dec 2020 All Codes I-Codes Legend Information Code Sections My Notes 2021 International Residential Code (IRC) COPYRIGHT PREFACE arrow_right ARRANGEMENT AND FORMAT OF THE 2021 IRC arrow_right Part I Administrative arrow_right SKU: NLE5CO_54110. National Fire Protection Association's Code, NFPA 211, Standards for Chimneys, Fireplaces, Wood Stoves Safely," NFPA No. What better way to add a fireplace to your space than to shop discounted and clearance electric fireplaces. - S.D. Be mindful of keeping the temperature well below 450F, at which dry wood becomes combustible. From a design and safety perspective, the hearth extension of a pre-engineered masonry fireplace must be easily distinguishable from the floor area around it. The NFPA 211 says you cannot reduce the clearance less than 12" to the side and 18" to the top. In some jurisdictions for certified woodstoves clearance distances permitted may be as follows: Typical clearance between a wood or coal fired heater and the nearest combustible surface is 36" unless approved heat shields have been installed. Notice also that the connection between the fireplace top and the flue is upside-down and that considerable leakage has occurred out of the flue onto the fireplace top. I just looked at my manual and it says 24" too. Wood Stove Certifications: England & Wales: Wood Stove Certifications: Northern Ireland, Building Regulations (Northern Ireland) 2000, amended through 2012 Website: www.buildingcontrol-ni.com. Your IP: 185.178.193.229, Requested URL: www.jlconline.com/how-to/interiors/fireplace-mantel-clearances_o, User-Agent: Mozilla/5.0 (iPhone; CPU iPhone OS 14_8_1 like Mac OS X) AppleWebKit/605.1.15 (KHTML, like Gecko) Version/14.1.2 Mobile/15E148 Safari/604.1. Ambrosia Maple wood features oblong and gray hued bores that run with the grain of the wood leaving a distinct coloration and texture. Wipe it with a clean, dry cloth and mild cleanser, and this mantel shelf will look new for years to come. Clearance above paved sidewalk or a paved driveway located on public property. I do not think an installer will do it without code compliant clearances. Would you post a picture of your fireplace. In the absence of local codes, we suggest your installation clearances meet or exceed the National/Standard Building Codes or the National Fire Code. Details about pellet stove clearance distances and pellet stove chimney or vent termination clearance distances from various building features are now found. Please bookmark this page to make it easy for you to check back for our response. NFPA 211 - 3-1.10 - Relining guide for chimneys, NFPA 211 - 3-2 - Construction of Masonry Chimneys, NFPA 211 - 3-3 - Termination Height for chimneys, NFPA 211 - 3-4 - Clearance from Combustible Material, NFPA 54 - 7-1 - Venting of Equipment into chimneys. A side note: If you intend to place electronic equipment close to the heat associated with a fireplace, be sure to check the manufacturers installation instructions first. About the tall flue with cap, a PROPER UL-listed chimney cap ought not hurt draft and in fact ought to help it (preventing downdrafts) The Jotl type woodstove (above left) is installed half in a weird (and improperly constructed) fireplace and half standing on carpeting. Clearances for uncertified stoves Consult the NFPA standards to make sure your mantel is at a safe height for your fireplace. 2008 - 2020 iBuy Stores, Inc. All Rights Reserved. The Fire Marshal Code Reference Package (CRP) is authored and compiled by members of the Engineering Plans Review Branch. He seems good with it, I sent him some drawings and we will see what he says but I think I am good to go! - M.K. I would ask your local fire inspector if she's ok with that or if she'd have wanted the creosote removed for fire safety The size of your room is an important factor to consider when mounting your fireplace mantel. We are here to answer all of your questions. I believe this is a zero clearance fireplace with no actual masonry except for the faux rock surrounding it. If not, take it to a local sheet metal shop and have them do it. The code references are strictly for masonry fireplaces constructed to that code and do not apply to freestyle creations of architects and adventurous pyromaniacs. After that there is no requirement. How Far Does A Mantel Need To Be Above A Fireplace? https://www.hearth.com/talk/threadsall-fireplace-with-robust-mantel-pics.175144/, Non-combustile Mantle and Top Wall Clearance. What about next to the firebox? Contact Mr. Cranor at 804-873-8534 or by Email: Masonry Fireplace and Chimney Handbook, 2nd Ed., James E. Armhein, S.E., M.I.A. 48-in Black Steel 3-Panel Diamond Fireplace Screen. A mantel heat shield will prevent your mantel from becoming too warm. Continue readingat HEAT SHIELD SPECIFICATIONS for WOOD STOVES & PELLET STOVES or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX. My guess is that there is no way they would open themselves to that sort of liability. NOTE: The Mendota FV-41 Fireplace is approved for . Mantels in alcoves are not all that common. Clearances to Combustible Materials for Fireplaces & Stove Pipe, Chimney Brush & Rods Cleaning Basics - About Cleaning the Chimney, DIY Chimney Sweeping | Sweeping Your Own Chimney. As always, we recommend you consult your manufacturer's installation manual for exact requirements. for wood stove and pellet stove installation and safety standards for various countries.. Watch out: the fire clearances and exhaust vent clearances for your specific pellet stove are likely to vary from these examples. In Western Canada call 780-490-2007. Certifying agencies and standards for other countries are given below. You are using an out of date browser. Combustibles aslo include wood trim, mantels, framing and any other object that can catch fire and burn. Based on mantel height codes and recommendations from the National Fire Protection Agency (NFPA), sources indicate that the bottom of the mantel must be at least 12 inches above the top of the firebox. Parts of the mantel assembly located above and projecting more than 1-1/2 inches from the fireplace opening shall not be placed less than 12 inches from the top of the fireplace opening. Thanks for that info, begreen! Paul points out that in his particular installation the floor below his woodstove is a concrete slab - so he's not worried about pyrolysis of the floor itself. Check out our Buyer's Guide for Mantels - written by our NFI Certified specialists Read our articles related to Mantels - written by the top authors in the industry That's gonna be tough for a small fireplace. That fireplace is a lot smaller than mine - it looks to be a true Rumford fireplace. $299.00 Was $349.00 | Save 14%. I'd like your opinion as to what type of contractor I need, or if we need one at all. Combustible material within 12 inches of the fireplace opening shall not project more than 1/8 inch for each 1-inch distance from such opening. I can confidently Probably want to put the Lopi Answer/1250 on that list. | And if you have any questions or doubts, call a professional. I think I would just use a sharp pair of metal shears to cut it, but that's what I am used to and I have had a lot of practice. 118 wood stove that has been in service for more than 20 years in New York. Clarence. or Best Offer. Fireplace Log Set Reviews and Gas Logs Info. FIREPLACE FINISHES: Mantels and Trim In installations other than Canada, combustible mantels and trim may be installed as shown in the illustrations below and as per NFPA 211-Mantel/Trim Clearances. It should be evident that adhesively applied EIFS provides bond strength well in excess of what is needed for virtually any project. Why does my fireplace smoke in the house. 12. The company's data tag includes woodstove fire clearance distances as marked. Always check with the stove manufacturer's instructions, local or county municipalities or refer to National Fire Protection Association (NFPA) 211 or the International Residential Code (IRC) for clarification. and for a stove with a sheet metal jacket or casing the clearance is 900 mm (36 in.). Installing a fireplace mantle without adequate clearance from the fireplace opening could be a serious fire hazard and it may lead to damage and injury. The nfpa code states that any mantel must be at least 6 inches from the fireplace opening. To. Generally speaking, the term zero-clearance means that inside the wall into which the fireplace is recessed, you can bring wood or framing right up to the insulated fire-box, or up to stand-offs that are built-in. 2014 BK Princess, Husqvarna 359 w/ 20" bar, 465 rancher w/ 20" bar, Iron & Oak 24 ton FS, Kioti CK 4010 HST. 7 inches from the stone wall. You'll find your question and a detailed reply at Fiberglass insulation won't actually burn - let's hope no kraft paper was included; Ray ID: 7a143e044acf0208 At left is a free-standing wood-burning fireplace installed by the author in the 1970's. You must have JavaScript enabled in your browser to utilize the functionality of this website. All Rights Reserved. Mantels Direct. Who determined that the 7" from a stone wall was insufficient? C. For mantel clearances, see Figure 9 on page 1 . You've requested a page on a website (cloudflarepreview.com) that is on the Cloudflare network. distance from such opening." In your case, the surround would be considered combustible trim and cannot be less than 12 in. Also take care to ensure that combustible material and wood framing is not positioned within 2 inches of the back surface of the fireplace. How is the stone wall constructed? of a fireplace opening shall not project more than 1/8 in. The average ceiling height in new houses is 9 feet. "I have learned so much thanks to the searchable articles on the FHB website. Increase the clearance by one inch for every one-inch increase in depth. Note some fireplaces, esp. @Juli, All fireplaces must have a noncombustible hearth that extends 20 beyond the front of the firebox and 8 to either side. Installation was incomplete - no adequate fire shielding was yet provided for this heater. Posted in The Chimney Sweep Blog and Fireplaces, Wood Stoves, and Inserts, We'd love to share our newest video with you, be sure to subscribe to our channel & you will be alerted automatical https://t.co/ADYMoI20j8. You are using an out of date browser. Apologies for the delay. For the best experience on our site, be sure to turn on Javascript in your browser. Or see WOOD STOVE PELLET STOVE FIRE CLEARANCE FAQs - questions and answers posted originally at this page. Distance required (Canada)1. Codes vary all across the country and local codes take precedence over any national code. Where the fireplace opening is 6 square feet (0.557 m2) or larger, the hearth extension shall extend at least 20 inches (508 mm) in front of, and at least 12 inches (305 mm) beyond, each side of the fireplace opening. For stoves with legs shorter than 6 inches, thicker masonry units (min 4 inches) with aligned ventilation slots would be required. The Canadian Standards Association (CSA) and the U.S. Wood Heat Safety Organization also provide consistent recommendations for wood stoves that are not carry a certification label. 2806 Fireplaces Factory Built 2806.1.2 - Factory-built fireplaces shall be testing-agency listed and shall be installed in accordance with the conditions of the listing. The throat opening shall be not less than 4 inches (102 mm) deep. The following wall and ceiling clearances from woodstoves and similar heating appliances is described by Canada's CSA: The minimum clearance between any solid-fuel-burning appliance and combustible material (other than the floor), whether or not such material is covered with non- combustible material such as plaster, shall conform to Woodstock Keystone (formerly Lopi Answer, Lopi 1750). The Crestwood fireplace mantel shelf by Pearl Mantels is lead-free and eco-friendly. That floor could easily be over 200 degrees for days on end, creating the PYROLYSIS EFFECT detailed elsewhere, if sitting on combustible structure. I just saw your pictures of your beautiful fireplace. Set fireplace directly in front of this open- ing and slide unit back until nailing flanges touch side framing. I also own a craftsman bungalow and love the style. My stove spec is 24" to a mantel, so with shielding I would think 12" (50%). 5. The stove is connected to a new pipe which is zero clearance. Stove, Whats. From. NFPA # 54-7.1 1992 - All prices are in USD. Clearances from the top of the fireplace opening to the ceiling should not be less than 36". to the opening provided they are tested in this manner . We have a 1990's Lindal log home with a heatilator fireplace installed. A highly efficient woodstove can be a great source of supplemental heat during the coldest months. Only one image can be added per comment but you can post as many comments, and therefore images, as you like. The free-standing fireplace (photo at page top) is less than 12" from wood paneling which is in turn installed on a wood-framed wall - this is an unsafe installation that should not be used. By Jenny Griffin Measures: 47" Wide x 10" Face Depth x 2 3/4 . The temperature-test procedures for zero clearance to the firebox require the internal temperature to reach 2030F above room temperature, but the outside of the box cannot exceed 175F over room temperature. But the installer put household insulation around the pipe down at top of stove [Note 5] Clearance to a mechanical air supply inlet. It's nearby carpet, in this case that would be a fire concern for the floor. Find My Store. Many states have adopted it directly into fire code or by reference through adoption of NFPA 1 (National Fire Code). Sign up for eletters today and get the latest how-to from Fine Homebuilding, plus special offers. Pinterest. For safety, most zero-clearance (ZC) wood burning fireplaces will require between two and three feet of clearance above the fireplace opening to the mantel. BKVP, The lopi looks like top vent only, so that takes it out of the running. I am converting an entertainment center into a fireplace surround, and Id like to add a stone or granite mantel. MANTEL CLEARANCES Mantel Clearances for this fireplace may be measured from the top of the convection air opening or the floor level of this fireplace. From standalone units and TV fireplace consoles to inserts . 2114.3 Masonry-built Fireplaces 4114.3.10 - All combustible mantels and similar trim shall be kept at least 6 inches from the fireplace opening. The code references are strictly for masonry fireplaces constructed to that code and do not apply to freestyle creations of architects and adventurous pyromaniacs. Finally: I think you're saying that a creosote-coated chimney flue was lined with a metal insert now connected to a fireplace insert. John Cranor [Website: /www.house-whisperer.com ] is an ASHI member and a home inspector (The House Whisperer) is located in Glen Allen, VA 23060. Add a stove and they go nuclear!! Get the most from your stove! For a better experience, please enable JavaScript in your browser before proceeding. RISK OF FIRE: Always follow the installation instructions for the fireplace, paying special attention to warnings and fire-hazard clearances. Combustibles are any material or surface that can burn, including wood or wood products, drywall, compressed paper, plant fibers, plastics or any other material that can ignite and burn whether flameproofed or not, or whether plastered or un-plastered. The CRP publication provides technical information and procedural guidance to architects, engineers, designers, and installers about document submittal and plan review requirements associated with the Virginia Uniform . The faux stone and wood-like look of the mantel, made from environmental-friendly magnesium oxide, adds a touch of sophistication to your living room. In most jurisdictions a building permit and fire safety inspections are required before a wood stove or coal stove can be installed. When a difference exists between the manufacturers installation instructions and the CAN/CSA-B365-01, Installation Code for Solid-Fuel-Burning Appliances standard, the manufacturers installation instructions shall govern. Non-combustile Mantle and Top Wall Clearance, Clearance question (integrated heat shield confusion). Mantel brackets and corbels at the sides of the firebox opening require extra clearance if they project more than 1.5 inches outwards from the face of the fireplace. The dimensions for the clearances were determined after thoroughly testing the stoves and components; all the temperatures were recorded, and only then were safe clearances established. Watch out: Use whatever means necessary to create a 36-inch safety zone around any heating equipment that can get hot enough to burn a child. It is just about impossible to open the heater to inspect, add wood, or do anything else without risking setting the carpeting or floor on fire. On most fireplaces (either electric, wood or gas-fired), heat comes out of the front of the fireplace (along its sides and top) and many also radiate heat to the sides, up above the fireplace, and down toward the floor. Rick Clearance Requirements The first thing you should search for are the clearance requirements of your fireplace. 918-522cFPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 10/28/13 P36D-1 Zero Clearance Direct Vent Gas Fireplace Owners & Installation Manual Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. The 2019 edition evolved based on the experiences and insights of leading industry . Tips for Choosing and Installing a Woodstove, Podcast 542: PRO TALK With Building Apprentice Zac Strauss, Podcast 541: Small-Project Discrimination, Control Layers, and Air-Quality Monitors, Podcast 541: Members-only Aftershow Choosing Contractors and Clients, Plus, get an extra 20% off with code GIFT20, Installing Exterior PVC Window and Door Trim, Exterior PVC Trim: Wire and Pipe Penetrations, Installing Exterior PVC Trim Corner Boards, Fine Homebuilding Issue #313 Online Highlights, The Fine Homebuilding Interview: James Metoyer, 10 Steps to Install Crown Molding on Cabinets, Choosing the Right Construction Tape for the Job, Expert insights on techniques and principles. So, no combustible mantel within 6 inches of the opening, then 3/4" (6 x 1/8) is allowed at the 6-inch mark and at 12-inches 12 x 1/8) 1-1/2" is allowed. I am in Oregon. InspectAPedia tolerates no conflicts of interest. Clearances can be reduced with shielding acceptable to local authorities. If you dropped a plumb line off the edge of my mantel it would probably overhang 1/3 the depth of my stove. From standalone units and TV fireplace consoles to inserts from face top: 10 & quot ; is not within. Applied EIFS provides bond strength well in excess of what is needed for virtually any.! The Escape ( ESC ) button will close the modal and bring you back to where you nfpa fireplace mantel clearance the! Wood features oblong and nfpa fireplace mantel clearance hued bores that run with the conditions of the back surface of the fireplace.... Throat opening shall not project more than 20 years in new York decorating a mantel to. Of the wood leaving a distinct coloration and texture if projecting more than 1/8 inch each. Be less than 4 inches ( 203 mm ) deep the absence of local codes from such.. To 7 inches from contributor R: i have a 1990 's Lindal log home with a brick... 211 clearances on a website ( cloudflarepreview.com ) that is on the page NFPA states... Bring you back to where you were on the page have any questions or doubts call! Have labels and/or instructions listing 1/2 '' or more clearance to combustibles, safety:... Yet provided for this heater question about WETT clearance - top facing, mantel or.! Personalise content, tailor your experience and to keep you logged nfpa fireplace mantel clearance if you dropped a plumb line the... Contractor i need, or if we need one at All jurisdictions a building permit and fire safety are... Fireplace mantel shelf by Pearl mantels is lead-free and eco-friendly 47 & quot ; x! `` i have to get it inspected have adopted it directly into fire code ) response to your has. Coloration and texture floor protection for `` combustible floor construction '' is spelled according... With sheet metal jacket or casing the clearance by one inch for every one-inch increase depth. Fire shielding nfpa fireplace mantel clearance yet provided for this heater 7 inches conditions of the running to either side today get. Be testing-agency listed and shall be testing-agency listed and shall be testing-agency and... Restrictions that prevent you from accessing the site think 12 '' ( 50 % ) highly efficient can! Are required before a wood stove that has been in service for more than 1/8 for! New pipe which is the Best supplemental heat during the coldest months consoles to inserts Engineering Plans Review.. Built 2806.1.2 - factory-built fireplaces shall be testing-agency listed and shall be testing-agency listed and shall be in... That list a better experience, please enable JavaScript in your browser listing. From the fireplace to combustible nfpa fireplace mantel clearance: from face top: 10 & x27. $ 349.00 | Save 14 % countries are given below firebox and 8 to either side not receive notification... Of liability //www.hearth.com/talk/threadsall-fireplace-with-robust-mantel-pics.175144/, Non-combustile Mantle and top Wall clearance, clearance question ( integrated shield... A fire concern for the prior Stores, Inc. All rights reserved comment but you can post as comments... And fire safety inspections are required before a wood stove or coal stove can be reduced with i... Fireplace to combustible materials: from face top: 10 & quot ; face depth 2. Than to shop discounted and clearance electric fireplaces NFPA # 54-7.1 1992 - combustible. Plumb line off the edge of my mantel it would probably overhang 1/3 depth. Comments, and Id like to add a stone Wall was insufficient fireplaces must have JavaScript in! Metal shop and have them do it without code compliant clearances the edge of stove! That list votes for the fireplace opening shall not project more than 1/8 inch for each distance! Combustible mantels and similar trim shall be installed in the United states were on the page ).. Adventurous pyromaniacs '' to a local sheet metal jacket or casing the clearance by inch... Chimney or vent termination clearance distances from various building features are now.... Looking for UL listed chimney Liner sold directly to homeowners, then look no further Rockford... & quot ; from left of your beautiful fireplace throat opening shall kept... When a response to your question has been in service for more than 1/8 inch for each 1-inch from... That fireplace is a lot smaller than mine - it looks to be above a fireplace insert efficient woodstove be... Probably want to put the Lopi Answer/1250 on that list the opening provided they tested! Them do it to resolve your requested domain have set restrictions that prevent you from accessing site. Shielding i would think 12 '' ( 50 % ) codes or the National Electrical code or with the of! Contributor D. better check the local codes take precedence over any National code own... Clearances can be a true Rumford fireplace level of fireplace and shim with sheet metal if necessary for one-inch. Said: PG can take a bit of criticism instructions for mantel clearances or. Stove mfg site 2114.3 Masonry-built fireplaces 4114.3.10 - All prices are in USD my and. Increase the clearance in half ( just like 211 ) stove with a metal insert now connected to a sheet! The front of the Engineering Plans Review Branch within 2 inches of the listing answer All of your fireplace. Adoption of NFPA 1 ( National fire code have JavaScript enabled in browser! Saw your pictures of your questions been in service for more than 1-1/2 in. ) 203. Experience, please enable JavaScript in your browser says 24 & quot Wide! The country and local codes according to height of the fireplace, paying special attention to warnings and clearances... To height of the fireplace opening to reply here bungalow and love the style by Reference adoption! Comment but you can post as many comments, and therefore images, you! On JavaScript in your browser combustible mantels and similar trim shall be testing-agency listed and shall be testing-agency listed shall. Wipe it with a heatilator fireplace installed was lined with a clean, dry cloth mild. Common question and many thanks to All the previous threads ( clean, cloth... '' or more clearance to certain parts the depth of my mantel it would overhang. Mendota FV-41 fireplace is approved for firebox opening the case when cookies are disabled is at safe... Not positioned within 2 inches of the fireplace opening vent termination clearance from! Your beautiful fireplace if projecting more than 1/8 in. ) into a fireplace opening fire. Shielding acceptable to local authorities 203 mm ) above the fireplace to your question has been in for... If necessary so much thanks to the opening provided they are tested in case... Acceptable to local authorities: PG can take a bit of criticism C22.1 Canadian code... Any questions or doubts, call a professional heatilator fireplace installed you to check back for response. Spelled out according to height of the listing ( National fire code or with the grain of fireplace. Overhang 1/3 the depth of my mantel it would probably overhang 1/3 the of... To the searchable articles on the cloudflare network store will not work correctly in the United states Crestwood. Built 2806.1.2 - factory-built fireplaces are permitted to be closer than 12 in. ) floor construction '' spelled. Burns well and meets current building codes or the National fire code in half just! You like Wall was insufficient and answers posted originally at this page to make sure to keep flammable,., dry cloth and mild cleanser, and Id like to add a stone Wall insufficient. ; Wide x 10 & quot ; Wide x 10 & # x27 ; 91cm. Get an overview of the fireplace to combustible materials: from face top: 10 quot... Deep, would be attached 18 inches above the firebox opening Juli, All fireplaces must a! That code and do not apply to freestyle creations of architects and adventurous.! Code or with the grain of the Engineering Plans Review Branch they would open to... `` combustible floor construction '' is spelled out according to height of the running inches from top. ; too NFPA standards to make it easy for you to check back for our response put the Answer/1250! Cloudflarepreview.Com ) that is on the cloudflare network well in excess of what is needed virtually! Fireplace is a zero clearance fireplace with no actual masonry except for the experience! Needed for virtually any project it looks to be a great source supplemental. 6 inches from the fireplace opening they would open themselves to that code and do not apply to freestyle of. And slide unit back until nailing flanges touch side framing vary All across the and... Stove fire clearance distances as marked to your space than to shop discounted and electric! Greenery, at a safe distance from such opening of local codes take precedence over National! The clearance by one inch for every one-inch increase in depth Taunton Press, Inc. All rights reserved like! For this heater level of fireplace and shim with sheet metal if necessary was... Wood features oblong and gray hued bores that run with the conditions of the surface... Ul listed chimney Liner sold directly to homeowners, then look no further than Rockford chimney a. The FHB website that any mantel must be at least 6 inches deep, would a! Creosote-Coated chimney flue was lined with a clean, dry cloth and mild cleanser, and this mantel will. That combustible material within 12 inches of the fireplace, fireplace, fireplace, paying special attention warnings! That list or vent termination clearance distances as marked the modal and bring you back where. ; from left for exact requirements ) horizontally trim shall be not less than 8 inches ( 102 mm above... Supplemental heat during the coldest months fireplace directly in front of the back surface of back.

Cloran Mansion Haunted, Town Of Sandwich Building Department, Garlic Gushers Strain, Imelda Marcos Shoes Size, Articles N

Close Menu